Definition and Purpose
The signals described in the previous blog posts, especially the T/A signal and the ASA signal, provide the CPU chip with the essential camera settings chosen by the user. What is still missing to calculate the actual shutter speed/aperture combination is the information about the brightness of the subject. In its A-series cameras, Canon represents the brightness by the brightness value (BV) of the APEX system. Based on this brightness value and the sensitivity value (SV; depends on film speed), the CPU chip can calculate the exposure value (EV) and, finally, the shutter speed and aperture to be used.
The center-weighted light sensor (photodiode) that measures the brightness of the subject through the lens is placed behind the prism, above the eyepiece of the viewfinder.
The OPT chip connected to the light sensor produces an analog voltage proportional to the brightness of the subject. Voltage ranges from about 0.95 V to about 1.20 V with a change of about 10 mV per BV. The voltage is passed to the Input chip where an analog/digital conversion is performed. This conversion results in a serial signal called the I-Bus signal (input bus). This signal is then sent to the CPU chip for further processing, especially the calculation of the corresponding exposure value (EV). The amplitude of the signal is about 1.0 V.
The I-Bus signal is more complex than the signals we have dealt with so far. In contrast to these signals, the I-Bus signal does not transmit the same word in each 240 µsec period. Instead, it is a time-sharing signal that transmits two semantically different words successively. Most of the time, a mode word is transmitted that contains information on the status of the camera (like, if the display is switched on or a power winder is attached). Only occasionally, about every 20 msec, a BV word is transmitted that contains information on the brightness value measured. That is, only in about every 80th period, a BV word is transmitted, in all other periods a mode word. Bit 7 of the mode word, called the ADCE flag (end of analog to digital conversion), states if the word transmitted next is a mode word (if ADCE = 0) or a BV word (if ADCE = 1).

(Consider that the Canon A-1 uses the “active low” logic where value ‘1’ of a bit is represented by a low voltage while value ‘0’ is represented by a higher voltage.)
In contrast to the signals we have dealt with so far, the BV word of the I-Bus signal does not represent a Gray code but a direct numerical value. Each bit of the word contributes to this value according to its position. Bit 0 represents 1/8 BV, bit 1 represents 1/4 BV, etc.

For example, the word 00101110 represents the brightness value 1/2 + 2 + 4 + 8 = 14.5 BV. In the Canon A-1, valid brightness values range from 0.875 BV (word 11100000) to 22.25 BV (word 01001101).
When the brightness value is used to check/adjust the accuracy of the light meter, Canon requests to compare the transmitted value with certain predefined octal values (octal = base-8 number). To convert the BV word to the corresponding octal value, do the following:
- Reverse the sequence of the bits of the BV word.
- Add prefix ‘0’ and split the bits in groups of three (triplets).
- Replace each triplet by the corresponding octal value
(000 → 0, 001 → 1, 010 → 2, 011 → 3, 100 → 4, 101 → 5, 110 → 6, 111 → 7).
To prevent confusion, octal numbers are postfixed with a subscripted ‘8’ in this blog post, like 1238.
Example: The BV word is 00101110. Reversing the sequence leads to 01110100. Splitting into triplets leads to 001|110|100. Replacing the triplets by their octal counterparts leads to 1648.
The Measurement
Test Point
The I-Bus signal can be measured at the I-Bus test point, also called test point 3 or TP-3. This test point is on the top side of the main flexible board, left of the viewfinder edge.
To use the SYNC signal as trigger, you have to connect a second test probe to TP-2.

Oscilloscope Settings
The I-Bus signal is quite complex, especially due to its time-sharing nature and the rarity of the transmission of BV words. Therefore, I suggest to display both the I-Bus signal and the SYNC signal on the oscilloscope to ease the interpretation of the data.
I suggest the following oscilloscope settings for Channel 1:
- DC coupling of the test probe
- horizontal scale (time base) 50 µsec/div
- vertical scale 500 mV/div, moved up by 1 V (= 2 div)
- signal trace inverted*
(* For easier interpretation of the transmitted word. Reason is the “active low” logic of the camera where value ‘1’ of a bit is represented by a low voltage while value ‘0’ is represented by a higher voltage.)
I suggest the following oscilloscope settings for Channel 2:
- DC coupling of the test probe
- vertical scale 1 V/div, moved down by 3 V (= 3 div)
If we would use the same, simple trigger as for the other signals (Channel 2, mode ‘Auto’, rising edge at level 1 V) we would rarely see the BV word on the oscilloscope (only in about 1% of the trigger events). In most cases, we would just see the mode word. Therefore, we have to use a more complex trigger that checks if the ADCE flag (bit 7 of the mode word) is set. Only in this case, we can be sure that the next word transmitted is the BV word. This type of trigger is called “pattern trigger” since it checks for a specific pattern of “High” and “Low” values on two or more channels. For our scenario, we have to check that bit 7 (the ADCE flag) of the I-Bus mode word has value ‘1’. We achieve this by defining a pattern trigger that combines Channel 1 (I-Bus signal) and Channel 2 (SYNC signal) with the logical operator AND where Channel 1 has to have a “High” value and Channel 2 has to have a “Low” value. The trigger distinguishes “High” from “Low” values by a trigger voltage that we set to -500 mV for Channel 1 (negative sign because we inverted the signal) and 500 mV for Channel 2. The ‘Time’ parameter of the trigger should by set to about 1 µsec.

(In rare situations, this trigger can also fire on a BV word if its bit 7 has value ‘1’. For this, the light meter has to measure a brightness of at least 16 BV. Don’t worry, just repeat the measurement.)
If your oscilloscope does not support pattern triggers, set a classic trigger for rising edge at level 1 V to Channel 2 instead. Then, activate the ‘History’ function of your oscilloscope and perform a measurement (a duration of one second is sufficient). Afterwards, scroll backwards through the stored signal trace until you find a mode word with the ADCE flag set. This word is directly followed by a BV word.
If your oscilloscope has a ‘Cursor’ function, set a X (time) cursor that starts 30 µsec after the trigger event (30 µsec = length of a bit) and is 240 µsec wide (240 µsec = length of a word). This cursor then encloses the BV word we’re interested in.
Test Environment
If you just want to check the I-Bus signal to see that the light meter is no broken and “somehow” reacts to light, no special test environment is needed. However, if you want to find out whether the light meter works correctly (and adjust it otherwise), you need a specific test environment:
- You have to attach a Canon FD 50mm f1.4 lens to the camera and focus it to infinity.
- You have to make sure that light reaches the light sensor only through the lens. This is important because the top cover of the camera is removed, exposing the light sensor. It will help to dim the light in the workshop and use a cloth or tape to block the light sensor from lateral light.
- You have to use a calibrated light source capable of producing specific EV values (typically, 9 EV, 12 EV, and 15 EV).
The test environment could look like this (using a Reveni Labs Camera Tester as calibrated light source):

Measurement

As can be seen, the measurement catched the BV word of the I-Bus signal, recognizable by the ADCE flag (bit 7) of the preceding mode word. The value of the BV word is 01110110 (= 1568). Considering the bit values described above, this value translates to 1/4 BV + 1/2 BV + 1 BV + 4 BV + 8 BV = 13.75 BV.
To check the calibration of the light meter, we need to determine the BV value measured for a brightness of 9 EV, 12 EV, and 15 EV.
(The spikes in the trace of the SYNC signal were probably caused by electrical noise of the light source used.)
In its service manual, Canon asks for a BV of 1428 (acceptable range 1368 to 1468) for 9 EV, a BV of 1728 (acceptable range 1668 to 1768) for 12 EV, and a BV of 2228 (acceptable range 2168 to 2268) for 15 EV. With 01100110 = 1468, 01111110 = 1768, and 10101001 = 2258, the light meter of the camera read a bit high but was still within the acceptable ranges. If the measurement was precise, the deviation of the light meter is about +1/3 EV. No adjustment of the light meter was performed.
Possible Errors
Signal Missing
If the signal is missing completely, check first if the power supply of the camera works correctly as well as the shutter release button. For example, half-press the shutter release button and check if the viewfinder display is working. If yes, both power supply and shutter release button should be OK.
Then, check if the SYNC signal is available and looks OK (see this blog post for details).
Otherwise, the light sensor, the OPT chip, the Input chip, or the connections in between might be broken. Also check that you removed the lens cap and the mirror is not flipped up.
Incorrect BV Word is Transmitted
If the measured BV value is not far from the value expected for the given brighness, the calibration of the light meter might be off and in need of adjustment. This can be done using two variable resistors (VRL, VRG). To change the BV value for EV 9, use VRG. To change the BV value for EV 15, use VRL. To change the BV value for EV 12, use both VRL and VRG. For details, see Canon’s service manual for the Canon A-1, pages 40-41.

If the measured BV value is way off, the light sensor might be dirty or partially damaged, the capacitor used for the analog/digital conversion might be out of specification, or there might be problems with the OPT chip or Input chip.